PLCLogger Tech Spec

 

 

 

 

 

Specifications - Data Sheet

 

 

FC-LOG Manual

 

Logger Intro Video

 

4GB MicroSD card will hold roughly 148,000,000 records in CSV format. Not enough? The logger is user upgradeable to 8GB, 16GB or 32GB.

 

 

 

Free videos below on how to use the logger (They are also preloaded on the logger when you receive it)

 

Check back for new videos. We will be adding to this list as we receive customer feedback.

 

Email us your suggestions.

 

 

 

Video List(click on the links below to download it and watch it):

 

 

 

1. General overview

 

2. Tool overview

 

3. Step by step instructions setting up the logger and a Directlogic PLC

 

4. Step by step instructions on setting up the logger and a CLICK PLC

 

5. Step by step instructions on setting up the logger and a DoMore PLC

 

6. Minor errors - errors such as minor communication - how do I know whats wrong

 

7. Major errors - configured for a CLICK but its plugged into a Directlogic

 

8. Pulse Stretch - Lengthen the bit the logger is looing at

 

9. RS232 / RS485 ports - The RS232 - RS485 port selection on the logger(what is it)

 

10. Firmware - How do you update the firmware

 

11. Major Upgrade - How do you do a major update to the logger

 

 

 

 

 

 

 

 

 

FIRMWARE FILE:

 

 

Future firmware upgrades

 

 

 

 

 

 

 

Sample Log Files

 

 

1 Sec Interval Log

 

Continous Poll 64,000 Records

 

Continous Poll 1,047,00 Records

 

 

Logs up to 55 Addresses.

 

4GB allows for roughly 148,000,000 records in CSV format.

 

User upgradable to 8GB, 16GB or 32GB.

 

Powers off of the 5VDC comm port on Automationdirect PLC's.

 

 

 

 

Logger to PLC Cables

 

  

The Logger ships "complete" with a cable that will allow you to plug it into the RJ12 port on the logger and the other end to the RJ12 port on the PLC. This cable has the same wiring and connectors as the DV1000 cable(DV-1000CBL). The C-More Micro uses the same cable. The RJ12 connector on the logger use the same pinout as the C-more Micro RJ12 connector. Therefore you can use any of the C-more Micro cables. The cable included provides your communication wires and your power wires to power the logger from the PLC. No external power is necessary when using this cable.  

 

If you need a new cable or you are going to plug the logger into a different style port on your PLC (such as the 15-pin high density D-Sub port on the 06, 250-1, 260 CPU's) you will need to check the cable required on pages 24 through 26 at:

 

https://www.automationdirect.com/static/specs/cmoremicro3t.pdf

 

If you are going to use the cable that comes with the logger and connect it to the 15-pin high density D-Sub port on the 06, 250-1, or 260 CPU's you will need the FA-15HD adapter from Automationdirect.

FA-15HD

 

Want us to help you configure your logger? Email us what you want your logger to do and we will email you back a simple text file to copy into your DATA directory on your logger and your all set